• DocumentCode
    577523
  • Title

    Cathode with end screens for relativistic magnetron

  • Author

    Vintizenko, I.I. ; Mashchenko, A.I. ; Mityushkina, V.Yu.

  • Author_Institution
    Institute of Physics and Technology at Tomsk Polytechnic University, av. Lenina 2a, Tomsk, 634050, Russia
  • fYear
    2012
  • fDate
    18-21 Sept. 2012
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    The results of application of cathode with end screens for relativistic magnetron microwave generators are presented. The increase in power of microwave radiation by 40-50% in comparison with the cathode without screens was obtained.
  • Keywords
    cathodes; magnetrons; microwave generation; cathode; end screens; microwave radiation; relativistic magnetron microwave generators; Anodes; Cathodes; Electron tubes; Flanges; Generators; Magnetic fields; Microwave oscillators; cathode with end screens; microwave generator; relativistic magnetron;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Strategic Technology (IFOST), 2012 7th International Forum on
  • Conference_Location
    Tomsk
  • Print_ISBN
    978-1-4673-1772-6
  • Type

    conf

  • DOI
    10.1109/IFOST.2012.6357775
  • Filename
    6357775