Cavity optimization for compact accelerator-based free-electron maser
Author :
Aryshev, A. ; Verigin, D. ; Araki, S. ; Fukuda, M. ; Karataev, P. ; Naumenko, G. ; Potylitsyn, A. ; Sakaue, K. ; Sukhikh, L. ; Terunuma, N. ; Urakawa, J.
Author_Institution :
KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan
fYear :
2012
fDate :
18-21 Sept. 2012
Firstpage :
1
Lastpage :
5
Abstract :
In previous works [1] we have successfully commissioned pre-bunched beam pumped free electron maser based on Stimulated Coherent Diffraction Radiation (SCDR) generated in an open resonator. An ultra-fast Schottky Barrier Diode (SBD) detector has enabled us to investigate the properties of the radiation in the range from 3 to 5 mm of wavelengths among broad frequencies stored in the cavity as well as the intrinsic properties of the cavity itself. We observed a turn-by-turn SCDR generated by a multibunch electron beam and directly measured the opened cavity quality factor of 11.4. In this report we represent the work directly related to optimization of both the maser system to achieve higher quality factor of the cavity essential to gain soft X-ray production via Thomson scattering in the next stage of the experiment and measurement system for better characterization of the maser light. One way of optimization is to minimize losses of energy due to transmission through resonator mirrors. For this purpose we have designed and constructed a test setup to investigate reflection and transmission properties of different mirror materials. Theoretical calculations have been performed using optical constants and theoretical models of electrical permittivity to compare with experimental results. In this report we summarize the experimental activity, represent new experimental results and represent steps undertaken to achieve the new resonator mirror design. For better understanding of the resonator performance a test of the SBD detector linearity is also demonstrated.
Keywords :
Q-factor; Schottky diodes; electron beams; free electron lasers; masers; Schottky barrier diode detector; Thomson scattering; accelerator-based free-electron maser; cavity optimization; electrical permittivity; electron beam; maser light; maser system; measurement system; mirror materials; open resonator; optical constants; quality factor; resonator mirror design; resonator mirrors; soft X-ray production; stimulated coherent diffraction radiation; wavelength 3 mm to 5 mm; Aluminum; Cavity resonators; Detectors; Mirrors; Optical resonators; Silicon; cavity optimisation; coherent radiation; diffraction radiation; maser; resonator; stimulated radiation; transmission coefficient;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Strategic Technology (IFOST), 2012 7th International Forum on
Conference_Location :
Tomsk
Print_ISBN :
978-1-4673-1772-6
Type :
conf
DOI :
10.1109/IFOST.2012.6357788
Filename :
6357788