• DocumentCode
    577853
  • Title

    Study on the temperature dual control of CSTR with coil cooling and jacket cooling and application

  • Author

    Zaiying, Wang ; Ying, Liu

  • Author_Institution
    Sch. of Electr. & Control Eng., Xi´´an Univ. of Sci. & Technol., Xi´´an, China
  • fYear
    2012
  • fDate
    6-8 July 2012
  • Firstpage
    3359
  • Lastpage
    3363
  • Abstract
    The CSTR is one of important equipments in chemical industry, and CSTR is above 90% of reactors used in main chemosynthesis material (plastic, synthetic rubber, synthetic fibre) production. Temperature dual control system solution is proposed based on analysis of CSTR structure with coil cooling and jacket cooling, and of insufficiency for temperature single loop control. The dual control system takes advantage of both coil cooling and jacket cooling so that both dynamic and static state performances of the control system get more satisfactory. Through theory analysis and semi-physical simulation, the advantage of the CSTR temperature dual control system is verified in control precision and dynamic response, and energy-saving and consumption reducing.
  • Keywords
    chemical industry; coils; cooling; temperature control; CSTR; chemical industry; chemosynthesis material production; coil cooling; jacket cooling; plastic; synthetic fibre; synthetic rubber; temperature dual control; temperature single loop control; Chemical reactors; Coils; Cooling; Process control; Valves; CSTR; Temperature dual control; coil cooling and jacket cooling; dynamic response and control precision; energy-saving and consumption reducing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Control and Automation (WCICA), 2012 10th World Congress on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4673-1397-1
  • Type

    conf

  • DOI
    10.1109/WCICA.2012.6358454
  • Filename
    6358454