DocumentCode :
579576
Title :
Introducing a bypass-backup connection system for current mode copper electrowinning intercell bars
Author :
Wiechmann, Eduardo P. ; Muñoz, Luis G. ; Aqueveque, Pablo E. ; Vidal, Guillermo A. ; Henríquez, J.A.
fYear :
2012
fDate :
7-11 Oct. 2012
Firstpage :
1
Lastpage :
6
Abstract :
The proposed system is suitable for current mode segmented intercell bars. These bars are immune to short circuits but sensitive to open circuits and dirt contacts. This new system adds segmented sidebars to interconnect in groups the otherwise electrically insulated cathode and anode hanger ends. The combination of a segmented main bar with these sidebars offers immunity to short circuits, open circuits and bypasses dirt contacts. Moreover, exhibits the best current balance ever reported ensuring high energy efficiency.
Keywords :
bars; cells (electric); electrochemical electrodes; anode hanger ends; bypass-backup connection system; current balance; current mode copper electrowinning intercell bars; dirt contacts; electric insulated cathode; high energy efficiency; open circuits; short circuits; Anodes; Cathodes; Intercell bars; Resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Society Annual Meeting (IAS), 2012 IEEE
Conference_Location :
Las Vegas, NV
ISSN :
0197-2618
Print_ISBN :
978-1-4673-0330-9
Electronic_ISBN :
0197-2618
Type :
conf
DOI :
10.1109/IAS.2012.6374082