DocumentCode
584164
Title
A study on locations of electrical discharge in a motor
Author
Nakayama, Kenichi ; Matsutake, Yukari ; Yanagisawa, Takahisa ; Takeda, Shigeki ; Kagoshima, Kenichi
Author_Institution
Grad. Sch. of Sci. & Eng., Ibaraki Univ., Hitachi, Japan
fYear
2012
fDate
Oct. 29 2012-Nov. 2 2012
Firstpage
716
Lastpage
719
Abstract
This paper have investigated the possibility of the insulation defect location of a stator by detection of electromagnetic wave. Sinusoidal voltage with 50Hz is applied between the stator and stator cores. And, the maximum antenna load voltage has been measured. The results which have been confirmed are: (1) the electrical discharge of location of insulation defect can be estimated in the applied voltage of PDIV. Detection of electrical discharge location is possible in applied voltage higher than PDIV by exploiting frequency of detected voltage. (2) the detection accuracy of the insulation defect location depends on polarization of a shielded loop antenna.
Keywords
discharges (electric); electromagnetic wave polarisation; loop antennas; machine insulation; stators; voltage measurement; PDIV; electric motors; electrical discharge location; electromagnetic wave detection; frequency 50 Hz; insulation defect location; maximum antenna load voltage measurement; shielded loop antenna polarization; sinusoidal voltage; stator cores; voltage frequency detection; Antenna measurements; Insulation; Partial discharge measurement; Partial discharges; Stator cores; Stator windings;
fLanguage
English
Publisher
ieee
Conference_Titel
Antennas and Propagation (ISAP), 2012 International Symposium on
Conference_Location
Nagoys
Print_ISBN
978-1-4673-1001-7
Type
conf
Filename
6394039