• DocumentCode
    585297
  • Title

    Assessment of human exposure to electromagnetic field from an intra-body communication device using intermediate-frequency electric field

  • Author

    Yoshino, Yuki ; Igo, Shota ; Katsuragi, Michihiko ; Taki, Masao

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Tokyo Metropolitan Univ., Tokyo, Japan
  • fYear
    2012
  • fDate
    17-21 Sept. 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Induced electromagnetic quantities were numerically calculated to assess the exposure to electromagnetic field from intra-body communication devices using electric near-field. Anatomically realistic human model was used for the calculations. The quantities include internal electric field, induced current, and specific absorption rate (SAR). Calculations were performed with finite-difference time-domain method with the accuracy check by means of comparison between analytical and numerical results for a sphere model. The calculated results of induced electromagnetic quantities were well below the basic restrictions of the ICNIRP guidelines. The results show that intra-body communication devices should not exceed exposure guidelines as far as the concept of the device is similar to the model assumed in this study.
  • Keywords
    bioelectric phenomena; biomagnetism; finite difference time-domain analysis; anatomically realistic human model; electromagnetic field; electromagnetic quantities; finite-difference time-domain method; human exposure assessment; induced electromagnetic quantities; intermediate-frequency electric field; internal electric field; intrabody communication device; numerical calculation; specific absorption rate;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC EUROPE), 2012 International Symposium on
  • Conference_Location
    Rome
  • ISSN
    2325-0356
  • Print_ISBN
    978-1-4673-0718-5
  • Type

    conf

  • DOI
    10.1109/EMCEurope.2012.6396783
  • Filename
    6396783