• DocumentCode
    585322
  • Title

    Calibration and using an electro-optical E-field sensor to study tuner panel and raised floor effects in a reverberation chamber

  • Author

    Schüür, Jens ; Kuhlmann, Christian ; Enders, Achim

  • Author_Institution
    Inst. for Electromagn. Compatibility, Tech. Univ. Braunschweig, Braunschweig, Germany
  • fYear
    2012
  • fDate
    17-21 Sept. 2012
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The construction of a reverberation chamber determines the overall quality factor of the chamber and also the uncertainty of field strength. Details are given in [1]. Especially in chambers constructed for large and heavy test objects a raised floor is installed on top of the ground shield. For the reverberation of the field a tuner is installed which needs a significant size for low frequencies. The quality factor should not be lowered by these installations. A lithiumniobate-based electro-optical field sensor system [2] is used to measure the electrical field between the raised floor, the ground shield and within a tuner paddle. First the sensor system is calibrated in a micro TEM-Cell and its results are verified in a larger TEM cell, a semi-anechoic room and in the empty reverberation chamber. Finally the change of field strengths caused by better shielding of the raised floor and tuner is given.
  • Keywords
    Q-factor; calibration; circuit tuning; electro-optical devices; reverberation chambers; sensors; calibration; electrical field measurement; electro-optical e-field sensor; field strength uncertainty; ground shield; lithiumniobate-based electro-optical field sensor system; microTEM-cell; quality factor; raised floor effect; reverberation chamber; semianechoic room; tuner paddle; tuner panel effect; Calibration; Floors; Probes; Q factor; Reverberation chamber; Sensitivity; Tuners; calibration; electro-optical sensor; quality factor; raised floor; reverberating chamber; shielding;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC EUROPE), 2012 International Symposium on
  • Conference_Location
    Rome
  • ISSN
    2325-0356
  • Print_ISBN
    978-1-4673-0718-5
  • Type

    conf

  • DOI
    10.1109/EMCEurope.2012.6396826
  • Filename
    6396826