DocumentCode :
585430
Title :
Medium voltage inverter for energy savings with kiln fan in cement industry
Author :
Andonov, Z. ; Gjorgjeski, D. ; Efremov, Z. ; Cvetkovski, Goga ; Jeftenic, Borislav ; Arsov, G.
Author_Institution :
Ekomozaik, Skopje, Macedonia
fYear :
2012
fDate :
4-6 Sept. 2012
Abstract :
In this paper energy saving possibilities with kiln fan in cement industry Usje are analysed. The fan is driven by medium voltage wound rotor induction motor and the air flow is controlled by a dumper. The drive works in steady state regimes for a long period and the possible energy saving depends on the dumper openness. For energy saving analysis, air flow and dumper pressure were measured and proper speed control is defined. The possible usage of existing motor and suitable medium voltage inverter, as well as, replacement with low voltage drives is analysed. Analysis is done taking into account the installation cabling and payback period of the equipment. At the end a final solution is proposed.
Keywords :
cement industry; energy conservation; fans; induction motor drives; invertors; rotors; air flow; cement industry; dumper; energy savings; installation cabling; kiln fan; low voltage drives; medium voltage inverter; medium voltage wound rotor induction motor; payback period; Capacitors; Induction motors; Inverters; Loss measurement; Low voltage; Medium voltage; Topology; energy savings; induction motor; kiln fan; medium voltage inverter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Motion Control Conference (EPE/PEMC), 2012 15th International
Conference_Location :
Novi Sad
Print_ISBN :
978-1-4673-1970-6
Electronic_ISBN :
978-1-4673-1971-3
Type :
conf
DOI :
10.1109/EPEPEMC.2012.6397262
Filename :
6397262
Link To Document :
بازگشت