Title :
Direct measurement of the energy spectrum of an intense proton beam
Author :
Leeper, R. J. ; Lee, J. R. ; Kissel, L. ; Johnson, D. J. ; Stygar, W. A. ; Hebron, D. E. ; Roose, L. D.
Author_Institution :
Sandia National Laboratories, Albuquerque, N.M. 87185, USA
Abstract :
A time resolved magnetic spectrometer has been used to measure the energy spectrum of an intense (0.5 TW/cm2) proton beam. A thin (2400 Å) gold foil placed at the focus of an ion diode Rutherford scattered protons by 90° into the spectrometer, reducing the beam intensity to a level suitable for magnetic analysis. The scattered beam was collimated by two 1 mm diameter apertures separated by 12.3 cm. The collimated protons were deflected in a 12.7 cm diameter, 6.65 Kg samarium-cobalt permanent magnet. The deflected protons were recorded simultaneously on CR-39 and eight 1 mm2 by 35 µm thick PIN diodes. A Monte Carlo computer code was used to calculate the sensitivity and resolution of the spectrometer. Data taken on Proto-I show a 150 keV to 250 keV wide proton energy spectrum at each instant in time.
Conference_Titel :
High-Power Particle Beams, 1983. HPPB. 5th International Conference on
Conference_Location :
San Francisco, CA, USA