Title :
Research on Electrical Fast Transient/Burst immunity test technology for electricity meter
Author :
Li Ming ; Jiang Yang ; Zheng Jianzhong ; Peng Xiaoxiao
Author_Institution :
Zhejiang Province Inst. of Metrol., Hangzhou, China
Abstract :
Aiming at the special problem of the Electrical Fast Transient/Burst (EFT/B) immunity test for electricity meter, design and development the corresponding power and pulse lines filters based on the simulation and analysis by using the EWB software, constructs the test system that can satisfy the requirements of electricity meter standard completely, also can always record the basic error values of electricity meter normally during the test process. The service condition indicated that this system is effective and accurate.
Keywords :
immunity testing; measurement standards; power filters; power meters; EFT-B; EWB software; development pulse line filter; electrical fast transient-burst immunity test technology; electricity meter standard requirement; error value recording; Electricity; Immunity testing; Load modeling; Magnetic separation; Power filters; Standards;
Conference_Titel :
Antennas, Propagation & EM Theory (ISAPE), 2012 10th International Symposium on
Conference_Location :
Xian
Print_ISBN :
978-1-4673-1799-3
DOI :
10.1109/ISAPE.2012.6408980