DocumentCode :
591862
Title :
System Development for Measuring the Arterious Venous Rate (AVR) for the Diagnosis of Hypertensive Retinopathy
Author :
Ortiz, D. ; Cubides, Mauricio ; Suarez, Almudena ; Zequera, M. ; Quiroga, Julian ; Gomez, Jairo Alejandro ; Arroyo, N.
Author_Institution :
Electron. Dept., Pontificia Univ. Javeriana, Bogota, Colombia
fYear :
2012
fDate :
7-9 Nov. 2012
Firstpage :
53
Lastpage :
56
Abstract :
The retinal blood vessels are very sensitive to the changes in the blood pressure. The changes in diameter of retinal vessels are an important sign of diseases such as hypertension, arteriosclerosis and diabetes, and may be used for the prevention of further consequences caused by the hypertension such as heart attack, brain stroke and renal failure. Those changes are reflected as arteriolar narrowing which changes the vessel caliber, and modify the arterious venous rate (AVR). Obtaining precise measurements of vascular widths is a critical and demanding process in automated retinal image analysis. A prototype system is developed for measuring the vessels caliber, calculates the AVR and determines the presence of Hypertensive Retinopathy. The process is implemented using different techniques of image and signal analysis including Gabor wavelet, gradients, morphological operations and Niblack. A classification algorithm is also implemented to separate veins from arteries. The diameter measurement is based on the image skeleton and the perpendicular segment of the vessel. The results obtained are presented.
Keywords :
biomedical optical imaging; blood pressure measurement; blood vessels; brain; cardiology; diseases; eye; image classification; image segmentation; medical image processing; sensitivity; wavelet transforms; Gabor wavelet; Niblack; arteriolar narrowing; arteriosclerosis; arterious venous rate measurement; automated retinal image analysis; brain stroke; classification algorithm; diabetes; diameter measurement; diseases; gradient operations; heart attack; hypertensive retinopathy diagnosis; image skeleton; morphological operations; optical imaging; perpendicular vessel segment; prototype system; renal failure; retinal blood vessels; retinal vessel diameter; sensitivity; signal analysis; system development; vascular widths; veins; vessel caliber; Biomedical imaging; Hypertension; Image segmentation; Retina; Retinopathy; Veins; Hypertensive Retinopathy; hypertension; image processing; retinal images;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Andean Region International Conference (ANDESCON), 2012 VI
Conference_Location :
Cuenca
Print_ISBN :
978-1-4673-4427-2
Type :
conf
DOI :
10.1109/Andescon.2012.22
Filename :
6424119
Link To Document :
بازگشت