DocumentCode
593825
Title
Regenerative AC electronic load with LCL filter
Author
Klein, R.L. ; de Paiva, A.F. ; Mezaroba, Marcello
Author_Institution
Dept. de Eng. Eletr., Univ. do Estado de Santa Catarina, Joinville, Brazil
fYear
2012
fDate
5-7 Nov. 2012
Firstpage
1
Lastpage
7
Abstract
This article present the design and implementation of a regenerative AC electronic load with LCL filter. The electronic load is composed by a current controlled rectifier, which drains from the equipment under test (EUT) the desired current profile, and a current controlled inverter connected to the grid, which is responsible for power regenerating. The control strategy, modeling and design of the controllers are presented. Experimental results on a prototype of 4.5 kVA are presented to validate the proposed system.
Keywords
electric current control; invertors; power filters; rectifiers; EUT; LCL filter; current controlled inverter; current controlled rectifier; current profile; equipment under test; regenerative AC electronic load; Capacitors; Damping; Frequency response; Power harmonic filters; Resonant frequency; Transfer functions; Voltage control; Electronic load; LCL filter; energy regeneration;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications (INDUSCON), 2012 10th IEEE/IAS International Conference on
Conference_Location
Fortaleza
Print_ISBN
978-1-4673-2412-0
Type
conf
DOI
10.1109/INDUSCON.2012.6452711
Filename
6452711
Link To Document