• DocumentCode
    594549
  • Title

    A calibration system for the Green Bank Telescope 4mm receiver: On-telescope, RFI-free calibration for 68–92 GHz observations

  • Author

    Watts, Galen

  • Author_Institution
    National Radio Astronomy Observatory, P. O. Box 2, Green Bank, West Virginia, 24944, USA
  • fYear
    2012
  • fDate
    Oct. 29 2012-Nov. 1 2012
  • Firstpage
    1328
  • Lastpage
    1330
  • Abstract
    Calibration for spectral line observations covering 68–92 GHz on the Green Bank Telescope uses a different calibration scheme than lower frequency receivers. In addition and extremely important is that any calibration scheme must not generate radio frequency interference (RFI) to other experiments ongoing at the Green Bank Observatory. An asynchronous logic network interfaces between the telescope control system, a brushless AC motor and three bit position encoding to place or remove reflectors, absorber or a quarter wave plate in the beam of the feeds to enable observers to calibrate their data during observations or configure the receiver for Very Long Baseline Interferometer network observations. This system is free of RFI that schemes utilizing more commonly available technology create.
  • Keywords
    calibration; logic circuits; millimeter receiver radiometry; radio astronomy; radiometer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference (EuMC), 2012 42nd European
  • Conference_Location
    Amsterdam, Netherlands
  • Print_ISBN
    978-1-4673-2215-7
  • Electronic_ISBN
    978-2-87487-026-2
  • Type

    conf

  • Filename
    6459339