DocumentCode :
601903
Title :
A model for calculating the magnetic & copper losses of an Inductive Power Transfer (IPT) pad
Author :
Malek, Hadi ; Wu, H.H.
Author_Institution :
Electr. & Comput. Eng., Utah State Univ., Logan, UT, USA
fYear :
2013
fDate :
17-21 March 2013
Firstpage :
2734
Lastpage :
2738
Abstract :
In this paper, an analytical expression is proposed to compute the total losses of a circular pad for Inductive Power Transfer (IPT) system. These losses can be separated into winding losses and core losses. The proposed analytical expression includes both conduction and induction losses due to eddy current effects at high frequency in the winding and ferrite core. Experimental results are shown to confirm the validity of the analytical model.
Keywords :
eddy currents; inductive power transmission; windings; analytical expression; circular pad; copper losses; core losses; eddy current effects; ferrite core; inductive power transfer pad; magnetic losses; winding losses;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition (APEC), 2013 Twenty-Eighth Annual IEEE
Conference_Location :
Long Beach, CA
ISSN :
1048-2334
Print_ISBN :
978-1-4673-4354-1
Electronic_ISBN :
1048-2334
Type :
conf
DOI :
10.1109/APEC.2013.6520682
Filename :
6520682
Link To Document :
بازگشت