DocumentCode
601937
Title
Improving the operation of microgrid interfaced inverter using L-type filter
Author
Elrayyah, Ali ; Sozer, Yilmaz
Author_Institution
Electrical and Computer Engineering Department, The University of Akron, OH, USA
fYear
2013
fDate
17-21 March 2013
Firstpage
2947
Lastpage
2952
Abstract
For microgrid interfaced sources, L-type filters are very useful for decoupling real and reactive power controls, but it has no voltage control loop. The absence of voltage loops complicates the implementations of virtual impedances and/or performing harmonics compensation. In this paper, methods are proposed to implement virtual impedances and compensate for the harmonics in L-type filters. The methods are verified by simulations and experimentally.
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition (APEC), 2013 Twenty-Eighth Annual IEEE
Conference_Location
Long Beach, CA, USA
ISSN
1048-2334
Print_ISBN
978-1-4673-4354-1
Electronic_ISBN
1048-2334
Type
conf
DOI
10.1109/APEC.2013.6520717
Filename
6520717
Link To Document