Title :
Subsea cable projects — Minimising risks
Author :
Goldring, R. ; Svoma, R.
Author_Institution :
Cambridge Marine Ltd., Cambridge, UK
Abstract :
The Authors have applied their combined experience of more than 50 years involvement in subsea cable projects, to present key issues and areas where effort must be applied to minimise the risk over the project life cycle. Pre-sanction engineering, manufacturing, installation and failure during operation are discussed. Specific issues are mentioned that have resulted in delay, cost escalation, reliability and availability in the past.
Keywords :
failure analysis; power cables; availability; cost escalation; delay; failure; installation; manufacturing; presanction engineering; project life cycle; reliability; risk minimisation; subsea cable projects; Asset Management. Condition Monitoring; FEED; Failures; HVDC; Installation. Disaster Recovery; Subsea Cables. Project Risk;
Conference_Titel :
AC and DC Power Transmission (ACDC 2012), 10th IET International Conference on
Conference_Location :
Birmingham
Electronic_ISBN :
978-1-84919-700-7
DOI :
10.1049/cp.2012.1949