The extrapolation factor for PLC radiation measurements in the 150–500 kHz frequency range
Author
Wachter, M. ; Koch, Martin ; Schwing, C. ; Hirsch, Holger
Author_Institution
Devolo AG, Aachen, Germany
fYear
2013
fDate
24-27 March 2013
Firstpage
220
Lastpage
224
Abstract
In order to compare radiation measurements in powerline communication systems, the detected values in the applied measurement distance need to be converted to a normative distance using an extrapolation factor. In this paper we determine the extrapolation factor within the frequency range 150 kHz to 500 kHz using analytical, numerical and experimental approaches.
Keywords
carrier transmission on power lines; extrapolation; PLC radiation measurements; applied measurement distance; extrapolation factor; frequency 150 kHz to 500 kHz; powerline communication systems; Antenna measurements; Electric fields; Electric variables measurement; Extrapolation; Frequency measurement; Magnetic field measurement; Magnetic fields; Electromagnetic compatibility; Extrapolation factor; Powerline communications; Radiation measurement;