Title :
Thermal management of high density power servers using a compact two-phase loop cooling system
Author :
Jeehoon Choi ; Minseok Ha ; Yunkeun Lee ; Graham, Samual ; Hwankook Kang
Author_Institution :
Zalman Tech Co. Ltd., Atlanta, GA, USA
Abstract :
With the increased usage of the internet and advances in computing hardware, the personal computing industry has shifted to lightweight mobile laptop platforms and the mobile internet devices. These personal computing devices are dependent on the cloud computing infrastructures that offer services delivered through data centers consisting of servers including multi-core semiconductor processors. Thermal management of most servers relies on a heat sink combined with fans providing forced air convection to reject heat to the ambient. However this conventional technique cannot accommodate the increased heat fluxes in the confined server enclosure and imposes a significant increase in noise, vibration, and power consumption. Innovative thermal management solutions must be employed to compensate for the increased heat dissipation in the space-constrained enclosures of high density power servers. In this paper, a compact two-phase loop cooling system was investigated to apply high density rack-mount server cooling applications. Experimental characterization shows that the system can reach a maximum heat flux of 22.22W/cm2 with thermal resistance of 0.136°C/W.
Keywords :
cooling; fans; forced convection; heat sinks; network servers; thermal management (packaging); cloud computing infrastructure; compact two-phase loop cooling system; computing hardware; confined server enclosure; data center; fans; forced air convection; heat dissipation; heat flux; heat reject; heat sink; high density power server; high density rack-mount server cooling applications; lightweight mobile laptop platform; mobile Internet device; multicore semiconductor processor; personal computing industry; power consumption; space-constrained enclosure; thermal management; thermal resistance; Heat sinks; Resistance heating; Servers; Thermal management; Thermal resistance; High density power seminconductor; Thermal management of server rack-mount enclosure; Two-phase loop cooling;
Conference_Titel :
Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM), 2013 29th Annual IEEE
Conference_Location :
San Jose, CA
Print_ISBN :
978-1-4673-6427-0
Electronic_ISBN :
1065-2221
DOI :
10.1109/SEMI-THERM.2013.6526801