• DocumentCode
    61112
  • Title

    Design of Different Self-Integrating and Differentiating Rogowski Coils for Measuring Large-Magnitude Fast Impulse Currents

  • Author

    Metwally, I.A.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Sultan Qaboos Univ., Muscat, Oman
  • Volume
    62
  • Issue
    8
  • fYear
    2013
  • fDate
    Aug. 2013
  • Firstpage
    2303
  • Lastpage
    2313
  • Abstract
    This paper presents the design and calibration of seven new Rogowski coils, namely, three air-cored coaxial-cable wound coils (RC1-RC3), one ferrite-cored varnished-wire wound coil (RC4), and three air-cored varnished-wire-wound coils (RC5- RC7). All coils are wound in a single layer and operated in the self-integrating mode, especially RC1-RC4. RC5-RC7 are mainly operated in the differentiating mode with external passive integrators. The designed seven coils are calibrated using different impulse currents up to 8.5 kA. These currents are simultaneously measured by different methods, namely, an impulse current transformer and a commercial Rogowski coil (ICT and CRC, respectively). Winding pitch advancement errors and magnetic fields into the plane of the coil are compensated by using a one-turn return loop placed inside the helical winding in the opposite direction to the pitch advancement for all coils except for RC4. It is found that all designed coils have a constant sensitivity of 0.2-4.4 V/kA over a certain bandwidth up to few MHz and with a very low sensitivity phase angle. For the self-integrating coils (RC1-RC3), increasing the number of turns and/or the former size enhances the coil response. For the differentiating coils with external integrators, the higher the integrator resistance and/or capacitance, the better the response (less droop effect and time shift) and the lower the sensitivity. The optimized termination resistance for the self-integrating coils and the integrator parameters for the differentiating coils enables the currents measured by RC3, RC4, and RC6 to have excellent agreement with those measured by ICT and CRC for different loads and levels without any droop effect.
  • Keywords
    coils; current transformers; integrating circuits; magnetic fields; transformer windings; Rogowski Coils; air-cored coaxial-cable wound coils; air-cored varnished-wire-wound coils; current 8.5 kA; ferrite-cored varnished-wire wound coil; helical winding; impulse current transformer; large-magnitude fast impulse currents; magnetic fields; passive integrators; self-integrating coils; winding pitch advancement errors; External integrator; Rogowski coil; frequency analysis; impulse-current measurement; transient analysis;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2013.2255994
  • Filename
    6516077