DocumentCode :
612420
Title :
The optimized filter width using in post-processing ESWAN data of prostate
Author :
Xizhen Wang ; Zhen Shen ; Peng Dong ; Xihe Sun ; Shanshan Gao ; Guanghui Chang ; Yanming Ge ; Bin Wang
Author_Institution :
Med. Imaging Center of the Affiliated Hosp., Weifang Med. Univ., Weifang, China
fYear :
2013
fDate :
25-28 May 2013
Firstpage :
475
Lastpage :
478
Abstract :
Object we investigate the optimal filter width in post-processing ESWAN data of prostate acquired with a 3T GE MRI. Methods Twenty-two patients with BPH were included in this study. Enhanced Susceptibility weighted angiography (ESWAN) was acquired using a TORSPOA coil in 3T MRI (GE Signa HDxt). All the data were transferred to the workstation (ADW4.5). SWAN software in Functool 2 was used to process the magnitude and phase images. Six filter widths were chosen in post-processing, which include 4, 8, 16, 32, 64 and 128. The magnitude and phase value of peripheral zone (PZ), central zone (CZ) and obturator internus were recorded. The magnitude and phase images were evaluated by two radiologists. Results The magnitude value of PZ, CZ and obturator internus were 1258.4±82.64, 1129 ± 52.04, 1042±59.58, respectively. The magnitude value of PZ was higher than those of CZ and obturator internus (P<;0.05). The phase of PZ were 0.017±0.143, 0.034±0.171, 0.032±0.181, 0.010±0.19, 0.014±0.189, -0.001±0.161. The phases of CZ were 0.074±0.086, 0.065±0.080, 0.039±0.093, 0.014±0.113, -0.030±0.094, -0.003±0.081. The phase values of PZ and CZ change dramatically with different filter width (P<;0.05). No The phase image of prostate with a filter width 16 was the best among all filter widths. Conclusion ESWAN of prostate can be processed with filter width 16 and 32 was good enough to obtain reliable results.
Keywords :
biomedical MRI; medical image processing; 3T GE MRI; BPH; ESWAN data postprocessing; Functool 2; GE Signa HDxt; SWAN software; TORSPOA coil; enhanced Susceptibility weighted angiography; magnetic flux density 3 T; optimized filter width; prostate; Biomedical imaging; Diseases; Magnetic resonance imaging; Magnetic separation; Magnetic susceptibility; Prostate cancer; ESWAN; filter width; post-processing; prostate;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Complex Medical Engineering (CME), 2013 ICME International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4673-2970-5
Type :
conf
DOI :
10.1109/ICCME.2013.6548294
Filename :
6548294
Link To Document :
بازگشت