DocumentCode :
614974
Title :
3D X-Ray microscopy: A non destructive high resolution imaging technology that replaces physical cross-sectioning for 3DIC packaging
Author :
Sylvester, Yuri ; Johnson, Bryant ; Estrada, Rolando ; Hunter, L. ; Fahey, Kevin ; Chou, Tso-Chu ; Kuo, Y.L.
Author_Institution :
Xradia, Inc., Pleasanton, CA, USA
fYear :
2013
fDate :
14-16 May 2013
Firstpage :
249
Lastpage :
255
Abstract :
In this paper, we describe the novel technique of using leading edge X-Ray Microscopy (XRM) technology to replace physical cross-sectioning in Failure Analysis (FA) and 3-Dimensional Integrated Circuit (3DIC) process development. Contrary to general consensus that 3D X-Ray is too slow, we explain how XRM can be used to obtain high quality cross-section images within 5-300 min per measurement depending on the physical properties (materials, feature sizes, and outer dimensions) of the sample and the minimum tolerable image quality needed to visualize a defect. The specifics of the inspection technique itself and how X-rays interact with the sample to achieve high-quality images will be discussed and contrasted with conventional 3D MicroCT technology. Furthermore, understanding the effects that imaging parameters, such as voltage, power, exposure time, resolution, number of projections, etc, have in the quality of an image, can help the user reduce the 3D X-Ray inspection time considerably. A TSMC test vehicle package is used to illustrate the effects of inspection time in image quality, and to compare and contrast the quality of an optical image taken from a physical cross-section and a virtual cross-section image taken from an XRM tomography.
Keywords :
X-ray microscopy; computerised tomography; failure analysis; inspection; integrated circuit packaging; three-dimensional integrated circuits; 3-dimensional integrated circuit; 3D X-ray inspection; 3D X-ray microscopy; 3DIC packaging; 3DIC process development; TSMC test vehicle package; XRM tomography; edge X-ray microscopy; failure analysis; nondestructive high resolution imaging technology; physical cross-sectioning; physical properties; virtual cross-section image; Computed tomography; Detectors; Materials; Microscopy; Spatial resolution; Three-dimensional displays; X-ray imaging; 3D X-Ray Microscopy; 3DIC; Computed Tomography; Failure Analysis; TSV; cracks; interposer; metrology; non-contact open; nondestructive inspection; underfill; voids;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Advanced Semiconductor Manufacturing Conference (ASMC), 2013 24th Annual SEMI
Conference_Location :
Saratoga Springs, NY
ISSN :
1078-8743
Print_ISBN :
978-1-4673-5006-8
Type :
conf
DOI :
10.1109/ASMC.2013.6552813
Filename :
6552813
Link To Document :
بازگشت