• DocumentCode
    616638
  • Title

    Detection of the impedance variation for nuclear control cable using time frequency domain reflectometry

  • Author

    Seung Jin Chang ; Chun Ku Lee ; Sin Ho Lee ; Jin Bae Park

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Yonsei Univ., Seoul, South Korea
  • fYear
    2013
  • fDate
    6-9 May 2013
  • Firstpage
    151
  • Lastpage
    156
  • Abstract
    In this paper, an impedance change localization for the nuclear control cable using the time-frequency domain reflectometry (TFDR) is proposed. The reference signal is designed by analyzing characteristics of the target cable and capacitive coupler. To be prepared for on-voltage experiment, the reference signal is injected into the target cable via capacitive coupler. The experiment using the TFDR and TDR is carried out to localize the impedance variation spot (0, 30, 50, 70, 90 Ω) in the target cable. Through the experiment, the accuracy of the proposed TFDR system is proved.
  • Keywords
    electric connectors; nuclear power stations; power cables; signal processing; time-domain reflectometry; time-frequency analysis; TFDR system; capacitive coupler; impedance change localization; impedance variation detection; impedance variation spot; nuclear control cable; on-voltage experiment; reference signal; target cable; time frequency domain reflectometry; Bandwidth; Correlation; Couplers; Impedance; Power cables; Signal resolution; Time-frequency analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2013 IEEE International
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4673-4621-4
  • Type

    conf

  • DOI
    10.1109/I2MTC.2013.6555400
  • Filename
    6555400