• DocumentCode
    616752
  • Title

    Monitoring dry-cask storage using thermoelectric powered wireless sensors

  • Author

    Carstens, T. ; Corradini, Michael ; Blanchard, J. ; Zhenqiang Ma

  • Author_Institution
    Dept. of Nucl. Eng., Univ. of Wisconsin-Madison, Madison, WI, USA
  • fYear
    2013
  • fDate
    6-9 May 2013
  • Firstpage
    747
  • Lastpage
    752
  • Abstract
    This paper describes using thermoelectric generators to power wireless sensors to monitor spent nuclear fuel during dry-cask storage. OrigenArp was used to determine the decay heat of the spent fuel at different times during the service life of the dry-cask. The Engineering Equation Solver program modeled the temperatures inside the spent fuel storage facility during its service life. The temperature distribution in a thermoelectric generator and heat sink was determined using the program Finite Element Heat Transfer. From these temperature distributions the power produced by the thermoelectric generator was determined as a function of the service life of the dry-cask. It was experimentally verified that a thermoelectric generator (HZ-14) with a DC/DC converter (Linear Technology LTC3108EDE) can power a transceiver (EmbedRF) based on the temperatures experienced during the service life of the dry-cask. Additional times beyond the design life of the dry-cask will be tested in order to find out when the transceiver does not have enough power to function. The broadcast period and transmission power level will influence the amount of power required from the thermoelectric generator.
  • Keywords
    DC-DC power convertors; finite element analysis; heat transfer; thermoelectric conversion; thermoelectric devices; wireless sensor networks; DC/DC converter; EmbedRF; decay heat; dry-cask storage; engineering equation solver program; finite element heat transfer; nuclear fuel; temperature distributions; thermoelectric generators; thermoelectric powered wireless sensors; transceiver; Generators; Heat sinks; Heat transfer; Sensors; Temperature; Transceivers; Transmitters; Dry-cask storage; thermoelectric; wireless sensor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2013 IEEE International
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4673-4621-4
  • Type

    conf

  • DOI
    10.1109/I2MTC.2013.6555515
  • Filename
    6555515