Title :
It is possible to resolve micrometer movements in B-mode images
Author :
Cinthio, M. ; Gerrebo, Annika ; Bengtsson, Martin ; Wallman, Lars ; Jansson, Tomas ; Persson, Hans W.
Author_Institution :
Fac. of Eng., Lund Univ., Lund, Sweden
Abstract :
We have proposed an echo localization estimator which theoretically gives infinite resolution in the axial direction in ultrasonic B-mode images during 1) echo structure tracking and 2) distance measurements of distinct echoes. The performance of the estimator was evaluated using a HDI5000 (Philips Medical Systems, Bothell, WA, USA) with a 35 mm 5-12 MHz linear array transducer. The resulting pixel size in the B-mode image was 100 m. The controlled setup consisted of a small water container lined with ultrasound absorber carpet and placed on a micrometer table, a triangulation laser (M5L/2, MEL Mikroelektronik GmbH, Eching, Germany) connected to a high-performance digital multimeter HP 34401A (Agilent Technologies, USA) and a thermometer TESTO 925 (Testo AG, Germany). In each of the three measurement series the micrometer table was moved approximately 15 m in 10-12 steps. The echo localization estimator succeeded to resolve the minute movement (<; 20 m) with high agreement with the reference method in all three series. The correlation was (R>0.998; p <;10-e38; 0.86<;k<;0.92). The standard deviation in the recorded 25 image cineloops ranged between 97 and 195 nm. Using BMode images with pixel size of 100 m as a base, our echo localization estimator can resolve micrometer movement accurately in a controlled set-up.
Keywords :
bioacoustics; biomedical measurement; biomedical transducers; biomedical ultrasonics; digital multimeters; distance measurement; micrometry; motion estimation; thermometers; Agilent Technologies; HDI5000; HP 34401A; M5L-2; MEL Mikroelektronik GmbH; Philips Medical System; axial direction; echo distance measurement; echo localization estimator; echo structure tracking; frequency 5 MHz to 12 MHz; high-performance digital multimeter; image cineloop recording; linear array transducer; micrometer movement; micrometer table; size 35 mm; thermometer TESTO 925; triangulation laser; ultrasonic B-mode image; ultrasound absorber carpet; water container; Acoustics; Arteries; Image resolution; Temperature measurement; Thickness measurement; Ultrasonic imaging; Ultrasonic variables measurement; diameter; distance estimator; distension; motion estimator; noninvasive ultrasound;
Conference_Titel :
Ultrasonics Symposium (IUS), 2012 IEEE International
Conference_Location :
Dresden
Print_ISBN :
978-1-4673-4561-3
DOI :
10.1109/ULTSYM.2012.0635