DocumentCode :
621551
Title :
A study on test image production using frequency domain correlation with convex function for radiographic inspection equipments
Author :
Kato, Yoichi ; Tanizaki, Tetsuya ; Yasukawa, Hiroshi
Author_Institution :
Aichi Prefectural University, Graduate School of Information, Science and Technology, 15223 Ibaraga-basama, Nagakute-shi, Aichi-pre., Japan
fYear :
2013
fDate :
28-31 May 2013
Firstpage :
1
Lastpage :
4
Abstract :
X-ray inspection is frequently used to inspect the solder bonds of surface-mounted components. This is especially true for LSIs since visual examination is made impossible because the package covers the BGA. The inherent instability of X-ray inspection and the low SNR of the resulting images are commonly offset by averaging a number of images; unfortunately, this increases the time taken. Our solution is to use fewer inspection images but achieve acceptable image quality by correlating them to a reference image by an image processing technique in the frequency domain.
Keywords :
Convex functions; Correlation; Inspection; Signal to noise ratio; Training data; X-ray imaging; BGA; convex function; correlation coefficient; training data;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics (ISIE), 2013 IEEE International Symposium on
Conference_Location :
Taipei, Taiwan
ISSN :
2163-5137
Print_ISBN :
978-1-4673-5194-2
Type :
conf
DOI :
10.1109/ISIE.2013.6563606
Filename :
6563606
Link To Document :
بازگشت