Title :
Comparison between 9-level hybrid asymmetric and conventional multi-level inverters for medium voltage application
Author :
Bahman, Amir Sajjad ; Blaabjerg, Frede
Author_Institution :
Center of Reliable Power Electronics (CORPE), Department of Energy Technology, Aalborg University, Pontoppidanstraede 101, DK-9220, Aalborg East, Denmark
Abstract :
A hybrid asymmetric 2-cell 9-level inverter is analysed and compared with two conventional multilevel inverters: the 9-level cascaded H-bridge and the 3-level diode clamped inverter, when used to drive an induction motor of 4.16kV/500kVA. In this analysis, Total Harmonic Distortion (THD), First Order Distortion Factor (DF1), power semiconductor losses, and efficiency are selected as performance indexes. The results indicate that the hybrid asymmetric topology has a better performance in performance indexes than the other topologies which leads to energy saving, better power quality and reduction in size, weight and volume of the LC-filter.
Keywords :
Harmonic analysis; Insulated gate bipolar transistors; Inverters; Medium voltage; Semiconductor diodes; Switches; Topology; Multi-level inverters; efficiency; medium voltage drives; power losses;
Conference_Titel :
Industrial Electronics (ISIE), 2013 IEEE International Symposium on
Conference_Location :
Taipei, Taiwan
Print_ISBN :
978-1-4673-5194-2
DOI :
10.1109/ISIE.2013.6563703