DocumentCode :
62364
Title :
A multiplicative model for improving microvascular flow estimation in dynamic contrast-enhanced ultrasound (DCE-US): theory and experimental validation
Author :
Barrois, Guillaume ; Coron, Alain ; Payen, Thomas ; Dizeux, Alexandre ; Bridal, Lori
Author_Institution :
Lab. d´Imagerie Parametrique, Univ. Pierre & Marie Curie (UPMC), Paris, France
Volume :
60
Issue :
11
fYear :
2013
fDate :
Nov-13
Firstpage :
2284
Lastpage :
2294
Abstract :
Perfusion parameter estimation from dynamic contrast-enhanced ultrasound (DCE-US) data relies on fitting parametric models of flow to curves describing linear echo power as a function of time. The least squares criterion is generally used to fit these models to data. This criterion is optimal in the sense of maximum likelihood under the assumption of an additive white Gaussian noise. In the current work, it is demonstrated that this assumption is not held for DCEUS. A better-adapted maximum likelihood criterion based on a multiplicative model is proposed. It is tested on simulated bolus perfusion data and on 11 sequences acquired in vivo during bolus perfusion of contrast agent in the cortex of healthy murine kidney, an area where the perfusion is expected to be approximately homogeneous. Results on simulated data show a significant improvement (p <; 0.05) of the precision and the accuracy for the estimations of perfusion parameters time to peak (TTP), wash-in rate (WiR), and mean transit time (MTT). On the 11 in vivo sequences, the new method leads to a significant reduction (p <; 0.05) in the variation of parametric maps for 9 sequences for TTP and 10 sequences for WiR and MTT. The mean percent decreases of the coefficient of variation are 40%, 25%, and 59% for TTP, WiR, and MTT, respectively. This method should contribute to a more robust and accurate estimation of perfusion parameters and an improved resolution of parametric imaging.
Keywords :
Gaussian noise; biomedical ultrasonics; data acquisition; haemodynamics; haemorheology; image resolution; image sequences; kidney; least squares approximations; maximum likelihood estimation; medical image processing; DCE-US theory; Gaussian noise; dynamic contrast-enhanced ultrasound theory; healthy murine kidney; in vivo image sequences; least squares criterion; linear echo power; maximum likelihood criterion; microvascular flow estimation; multiplicative model; parametric imaging; perfusion parameter estimation; simulated bolus perfusion data; Data models; Estimation; Noise; Parametric statistics; Standards; Suspensions; Ultrasonic imaging; Animals; Computer Simulation; Contrast Media; Image Processing, Computer-Assisted; Kidney; Least-Squares Analysis; Mice; Phospholipids; Reproducibility of Results; Sulfur Hexafluoride; Ultrasonography;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2013.6644733
Filename :
6644733
Link To Document :
بازگشت