Abstract :
The classical therapeutic applications based on ultrasound is one of the most widely and frequently used technique to treat people with pain, musculoskeletal injuries, and soft-tissue lesions. Despite the research already made on ultrasonic therapy devices, it is well known that an explanation of the real behavior of the radiation patterns in commercial physiotherapy applicators hardly has been investigated. Thus, it is of interest to make new extensive evaluations of these aspects to facilitate proposals of thermal treatments over delimitated areas with enough precision and patient safety. This work presents a comparative experimental evaluation of the acoustic patterns produced by two ultrasonic therapy applicators, of the same series and model in a commercial company. Some anomalous unexpected radiations observed in the near zones of both devices have been analyzed, showing unhomogeneities of very distinct magnitude in each one; their possible origins are analyzed. An authors´ modeling of the complex radiation in such therapeutic applicators is improved to numerically simulate these radiated CW fields. Numerical results approach in part experimental radiated patterns, which would explain a possible origin of the spurious radiations and their influence on the effectively measured ultrasonic fields.
Keywords :
biomedical equipment; biothermics; numerical analysis; ultrasonic therapy; acoustic pattern; applicator housing; classical therapeutic application; commercial physiotherapy applicator; comparative experimental evaluation; expected radiation pattern; musculoskeletal injury; nonideal radiation; numerical simulation; pain; patient safety; radiated CW field; soft-tissue lesion; spurious radiation; thermal treatment; ultrasonic field; ultrasonic therapy applicator; ultrasonic therapy device; ultrasonic thermal therapy; Conferences; Couplings; Decision support systems; IEEE catalog; Medical services; Ultrasonic fields; applicator housing; modeling; non-ideal radiation patterns; thermal therapy;
Conference_Titel :
Health Care Exchanges (PAHCE), 2013 Pan American
Conference_Location :
Medellin
Print_ISBN :
978-1-4673-6254-2
DOI :
10.1109/PAHCE.2013.6568339