DocumentCode :
626771
Title :
Steady state reliability of maximum power point tracking algorithms used with a thermoelectric generator
Author :
Laird, Ian ; Lu, D.D.C.
Author_Institution :
Sch. of Electr. & Inf. Eng., Univ. of Sydney, Sydney, NSW, Australia
fYear :
2013
fDate :
19-23 May 2013
Firstpage :
1316
Lastpage :
1319
Abstract :
A thermoelectric generator (TEG) with its near linear V-I characteristic makes its operation distinct from a photovoltaic (PV) cell. However, when maximum power point tracking (MPPT) is implemented in TEG power electronic systems, the established knowledge and wisdom surrounding PV oriented MPPT systems is often applied directly without consideration of the TEG´s characteristics. Unsuitable MPPT algorithms generate large operating point variations thus deteriorating the steady state performance of the TEG. Therefore an algorithm that can reliably deliver power with low steady state error over a range of operating conditions is desired. This paper compares three common MPPT methods (perturb and observe, power gradient tracking and fractional open-circuit voltage / short-circuit current), in terms of their steady state performance and reliability, when used with a 4.2 V, 3.4 A (for matched load at ΔT = 270°C) TEG module. Experimental results are reported that confirm better and more reliable steady state performance of the fractional open-circuit voltage / short-circuit current method compared to the perturb and observe and power gradient tracking algorithms.
Keywords :
maximum power point trackers; reliability; solar cells; thermoelectric conversion; PV cell; PV-oriented MPPT systems; TEG module; TEG power electronic systems; current 3.4 A; fractional open-circuit voltage-short-circuit current MPPT method; linear V-I characteristic; maximum power point tracking algorithm; operating point variation; perturb and observe MPPT method; photovoltaic cell; power gradient tracking MPPT method; steady state error; steady state performance; steady state reliability; temperature 270 degC; thermoelectric generator; voltage 4.2 V; Current measurement; Generators; Maximum power point trackers; Short-circuit currents; Steady-state; Temperature measurement; Voltage measurement; Thermoelectric energy conversion; Tracking;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Circuits and Systems (ISCAS), 2013 IEEE International Symposium on
Conference_Location :
Beijing
ISSN :
0271-4302
Print_ISBN :
978-1-4673-5760-9
Type :
conf
DOI :
10.1109/ISCAS.2013.6572096
Filename :
6572096