  • Abstract
    With the increasing use of inverter-controlled traction motor systems in electric rail, road, and off-road vehicles, protecting motor bearings will become a key requirement for reliability. Partial mitigation measures against inverter-induced electrical bearing damage can merely shift the damage to gearbox bearings and create more maintenance headaches. In some vehicles, stray currents can also cause electromagnetic interference (EMI) and/or radio frequency interference (RFI) that can jeopardize electronic control systems. The best long-term solution is a contact/noncontact motor shaft grounding ring that works in the unique electric vehicle environment of high revolutions per minute (r/min), rapid acceleration, etc.
  • Keywords
    electric vehicles; gears; invertors; machine bearings; reliability; traction motor protection; EMI; RFI; contact motor shaft grounding ring; electric rail; electric vehicle environment; electromagnetic interference; electronic control systems; gearbox bearings; inverter-controlled traction motor systems; inverter-driven traction motors; inverter-induced electrical bearing damage; lurking problem; motor bearing protection; noncontact motor shaft grounding ring; off-road vehicles; partial mitigation measures; radiofrequency interference; reliability; stray currents; Electric vehicles; Electromagnetic interference; Grounding; Inverters; Shafts; Traction motors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Transportation Electrification Conference and Expo (ITEC), 2013 IEEE
  • Conference_Location
    Detroit, MI
  • Print_ISBN
    978-1-4799-0146-3
  • Type

    conf

  • DOI
    10.1109/ITEC.2013.6573484
  • Filename
    6573484