DocumentCode :
627946
Title :
Parameter Estimation of Auditory Saccades and Visual Saccades
Author :
Xiu Zhai ; Ghahari, Alireza ; Enderle, J.D.
Author_Institution :
Dept. of Biomed. Eng., Univ. of Connecticut, Storrs, CT, USA
fYear :
2013
fDate :
5-7 April 2013
Firstpage :
185
Lastpage :
186
Abstract :
Saccadic eye movements induced by visual stimuli (V-saccade), auditory stimuli (A-saccade) and auditory-visual stimuli (AV-saccade) were recorded and analyzed. SMI Hi-Speed eye tracking system was used to collect human saccade data. A FORTRAN program designed to compute parameter estimates for a 1D saccadic eye movement model was used for data analysis. The controller for saccadic eye movements in response to the three different types of stimuli were compared. System parameters of agonist pulse and post-inhibitory rebound burst (PIRB) in the antagonist motoneurons that caused post-saccade phenomena were also estimated. A-saccade exhibited lower agonist pulse magnitude and longer agonist pulse duration in large saccade amplitude. Antagonist onset delay was longer in A-saccade for saccades of the same size. There was a higher incidence of dynamic overshoot in A-saccade, while more in the abducting than adducting direction.
Keywords :
biomechanics; biomedical imaging; eye; hearing; medical image processing; neurophysiology; parameter estimation; physiological models; 1D saccadic eye movement model; A-saccade; AV-saccade; FORTRAN program; PIRB; SMI Hi-Speed eye tracking system; abducting direction; adducting direction; agonist pulse duration; agonist pulse magnitude; antagonist motoneuron; antagonist onset delay; auditory saccade parameter estimation; auditory stimuli; auditory-visual stimuli; data analysis; dynamic overshoot incidence; human saccade data collection; post-inhibitory rebound burst; post-saccade phenomena; saccade amplitude; saccadic eye movement controller; visual saccade parameter estimation; Biomedical engineering; Computers; Delays; Parameter estimation; System identification; Tracking; Visualization; agonist pulse; antagonist pulse; auditory saccade; auditory-visual saccade; post-inhibitory rebound burst; visual saccade;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioengineering Conference (NEBEC), 2013 39th Annual Northeast
Conference_Location :
Syracuse, NY
ISSN :
2160-7001
Print_ISBN :
978-1-4673-4928-4
Type :
conf
DOI :
10.1109/NEBEC.2013.123
Filename :
6574420
Link To Document :