Abstract
This paper discusses the effects of unexpected bi-directional operation of Phase-Shift Full-Bridge Converter in cold redundancy (CR). According to growing trends for high efficiency at light-load, cold redundancy method is strongly required in parallel operation system. However, because of unexpected backward operation, the voltage stress of primary switches is severely increased. In this paper, the period of mode change from normal operation to backward operation is investigated. The detailed operations in backward mode are described and the main factors of the severe voltage stress are analyzed. Furthermore, characteristics of switch to reduce higher voltage stress are also presented in terms of selecting switches. The validity of this study is confirmed by the experimental results of prototype 1.6kW converters.
Keywords
power convertors; CR; cold redundancy method; parallel operation system; phase-shift full-bridge converter; power 1.6 kW; primary switches; switch characteristics; unexpected backward operation; unexpected bidirectional operation; voltage stress reduction; Irrigation; Moon; Switches;
fLanguage
English
Publisher
ieee
Conference_Titel
ECCE Asia Downunder (ECCE Asia), 2013 IEEE
Conference_Location
Melbourne, VIC
Print_ISBN
978-1-4799-0483-9
Type
conf
DOI
10.1109/ECCE-Asia.2013.6579229
Filename
6579229
Link To Document