Abstract
A computationally simple method is demonstrated for automated identification of probable steady state and probable transient state in noisy flow rate process signals of a pilot-scale absorption column. The method is shown effective even when noise amplitude changes, and to several types of disturbance.
Keywords
absorption; chemical engineering computing; identification; signal denoising; statistical analysis; computationally simple method; noise amplitude; noise disturbance; noisy flow rate process signal; pilot-scale absorption column; steady state identification; transient state identification; Correlation; Market research; Noise; Orifices; Steady-state; Transient analysis; Visualization;