Abstract
In this paper measured results are presented to show the effect of shielding slots, seems and cables interconnecting different subsystems on the radiated emissions. It is shown that by using proper shielding Radiated Emission (RE) levels can be reduced by as much as 40dB. Similarly the attenuation of at least 20 dB in measured voltage levels in the conducted emission tests can be achieved by the use of π-filters and chassis ground. In case of power unit, it has also been diagnosed that major cause of conducted emissions (CE) is the switching of DC-DC convertor. Measurements with ferrite beads showed that these are useful only at frequencies below few megahertz.
Keywords
DC-DC power convertors; earthing; electromagnetic interference; electromagnetic shielding; ferrites; filters; π-filters; DC-DC convertor; EMI filters; chassis ground; conducted emissions; ferrite beads; grounding; radiated emissions; shielding effect; shielding slots; Cable shielding; Converters; Electromagnetic interference; Frequency measurement; Power cables; Power measurement; Signal processing; Conducted Emissions (CE); Conducted Susceptibility (CS); Electromagnetic Interference (EMI); Electromagnetic compatibility (EMC); LISN (Line Impedance Stabilization Network); Radiated Emissions (RE); Radiated Susceptibility (RS);
fLanguage
English
Publisher
ieee
Conference_Titel
Recent Advances in Space Technologies (RAST), 2013 6th International Conference on
Conference_Location
Istanbul
Print_ISBN
978-1-4673-6395-2
Type
conf
DOI
10.1109/RAST.2013.6581278
Filename
6581278
Link To Document