DocumentCode
63360
Title
Direct and indirect lightning tests to the Z11 helicopter radome in China
Author
Duan Zemin ; Si Xiaoliang ; Feng Jie ; Duan Jingbo ; Ni Youyuan ; Li Xin ; Chen Rongbao ; Sun Anhong
Author_Institution
Hefei Hang Tai Electrophys. Technol. Ltd. of AVIC, Hefei, China
Volume
20
Issue
4
fYear
2013
fDate
Aug-13
Firstpage
1112
Lastpage
1116
Abstract
A 4.8 MV impulse voltage generator and impulse current generators are used to perform lightning simulation on the Z11 helicopter radome. The radome system is composed of lightning diverter strips, air data probe and a 0.5 m long metal structure attached to the radome to simulate the helicopter body. The test facilities, process and the results are presented according to the Chinese CCAR27 standard. This test improved considerably the lightning protection performance of the Z11 radome system by optimizing the diverters. This resulted in successful passing of ground simulated lightning test requirements.
Keywords
aircraft antennas; aircraft testing; helicopters; lightning protection; pulse generators; radomes; standards; Chinese CCAR27 standard; Z11 helicopter radome; air data probe; helicopter body; impulse current generators; impulse voltage generator; lightning diverter strips; lightning protection test; lightning strike tests; voltage 4.8 MV; Aerospace electronics; Generators; Helicopters; Lightning protection; Strips; EMC; Lightning protection tests; RAMI; helicopter; high voltage; radome;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2013.6571424
Filename
6571424
Link To Document