  • Abstract
    Two new preparation methods of silicon substrates in the observation of micro-joint and micro-bumps failure mode were proposed in this study. One method is to use tilted grinding on 3DIC substrate to navigate the failed micro-joints. The other method can provide wider cross-section range by using ion polishing system studied in iST.
  • Keywords
    grinding; integrated circuit interconnections; integrated circuit packaging; integrated circuit reliability; integrated circuit testing; polishing; silicon; three-dimensional integrated circuits; 3D IC microbumps observation; Si; ion polishing system; microbumps failure mode; microjoint failure mode; sample preparation; tilted grinding; Copper; Electromigration; Failure analysis; Milling; Physics; Reliability; Substrates;