Abstract :
This paper describes a failure analysis on a commercial MEMS microphone after a test according to the standard of Mil-Std-883. With the help of test and a finite element simulation, we find that the studied MEMS part of the microphone can survive a stress limit above 20000g normal to the diaphragm plane. Under a constant acceleration high to 30000g, the diaphragm breaks and the devices fail.
Keywords :
finite element analysis; micromechanical devices; microphones; semiconductor device reliability; semiconductor device testing; stress effects; Mil-Std-883 standard; commercial MEMS microphone; constant acceleration; failure analysis; finite element simulation; mechanical reliability; stress limit; test; Acceleration; Micromechanical devices; Microphones; Reliability; Silicon; Standards; Stress; MEMS; Mechanical Reliability; Microphone;