• DocumentCode
    636560
  • Title

    Real-time comparison of conventional direct control and pattern recognition myoelectric control in a two-dimensional Fitts´ law style test

  • Author

    Wurth, Sophie M. ; Hargrove, Levi J.

  • Author_Institution
    Swiss Fed. Inst. of Technol. in Lausanne, Lausanne, Switzerland
  • fYear
    2013
  • fDate
    3-7 July 2013
  • Firstpage
    3630
  • Lastpage
    3633
  • Abstract
    Few studies have directly compared real-time control performance of pattern recognition to direct control for the next generation of myoelectric controlled upper limb prostheses. Many different implementations of pattern recognition control have been proposed, with minor differentiations in the feature sets and classifiers. An objective and generalizable evaluation tool quantifying the control performance, other than classification accuracy, is needed. This paper used the implementation of such a tool through the design of a target acquisition test, similar to a Fitts´ law test, relating movement time of the target acquisition to the difficulty of the target, for a given control strategy. Performance metrics such as throughput (bits/sec), completion rate (%) and path efficiency (%) allow for a complete evaluation of the described strategies. We compared direct control and pattern recognition control with the proposed test and found that 1) the test was valid for control system evaluation by following Fitts´ law with high coefficients of determination for both types of control and 2) that pattern recognition significantly outperformed direct control in throughput with similar completion rates and path efficiencies. In this framework, the present pilot study supports pattern recognition as a promising strategy and forms a basis for the development of a general and objective tool for the performance evaluation of upper limb control strategies.
  • Keywords
    bioelectric phenomena; medical control systems; medical signal processing; pattern recognition; prosthetics; signal classification; 2D Fitts law style test; classifiers; control system evaluation; conventional direct myoelectric control; feature set; myoelectric controlled upper limb prostheses; pattern recognition control; pattern recognition myoelectric control; real time control performance; target acquisition test; upper limb control strategies; Biomedical engineering; Control systems; Electromyography; Pattern recognition; Prosthetics; Real-time systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
  • Conference_Location
    Osaka
  • ISSN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2013.6610329
  • Filename
    6610329