DocumentCode :
636927
Title :
Estimation of removed uremic toxin indoxyl sulphate during hemodialysis by using optical data of the spent dialysate
Author :
Holmar, Jana ; Uhlin, Fredrik ; Ferenets, Rain ; Lauri, Kai ; Tanner, Risto ; Arund, Jurgen ; Luman, Merike ; Fridolin, Ivo
Author_Institution :
Dept. of Biomed. Eng., Tallinn Univ. of Technol., Tallinn, Estonia
fYear :
2013
fDate :
3-7 July 2013
Firstpage :
6707
Lastpage :
6710
Abstract :
The aim of this study was to explore the possibility to determine the amount of total removed Indoxyl Sulphate (TR_IS) during dialysis session, an optical method utilizing absorbance and fluorescence spectral data of the spent dialysate was used. Eight uremic patients from Linköping, Sweden and 10 from Tallinn, Estonia, were studied during dialysis treatments. Dialysate samples were taken during each treatment and analyzed at a laboratory. Fluorescence and absorbance spectra of the spent dialysate were measured with spectrofluorophotometer and spectrophotometer. The spectral values were transformed into IS concentration using multiple linear regression model from the total material noted as optical method (Opt). IS concentration was estimated using high-performance liquid chromatography (HPLC) method as a reference. TR_IS values were calculated. Achieved results were compared regarding mean values and SD and collated with the amount of total removed urea value (TR_Urea) for the same dialysis procedures. Mean TR value±SD (mg) for urea was 28 947±9 241; TR for IS was 151.4±87.3 estimated by HPLC and 149.4±84.9 estimated by Opt. The TR_IS values were not significantly different (p≤0.05). This study indicates, that it is possible to estimate TR_IS using only spectral values of the spent dialysate and the parameter can be used for quantifying the elimination of protein bound uremic toxins during the dialysis procedure.
Keywords :
biochemistry; chromatography; diseases; fluorescence; molecular biophysics; patient treatment; proteins; regression analysis; spectrochemical analysis; spectrophotometers; toxicology; absorbance spectral data; dialysis treatment; fluorescence spectral data; hemodialysis; high-performance liquid chromatography method; multiple linear regression model; optical method; protein bound uremic toxin; spectrofluorophotometer; spectrophotometer; spent dialysate; total removed indoxyl sulphate determination; total removed urea value; uremic patient; uremic toxin indoxyl sulphate estimation; Biomedical optical imaging; Estimation; Fluorescence; Kidney; Optimized production technology; Protein engineering; Proteins; Aged; Aged, 80 and over; Dialysis Solutions; Female; Humans; Indican; Male; Middle Aged; Renal Dialysis; Spectrometry, Fluorescence;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location :
Osaka
ISSN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2013.6611095
Filename :
6611095
Link To Document :
بازگشت