DocumentCode
636927
Title
Estimation of removed uremic toxin indoxyl sulphate during hemodialysis by using optical data of the spent dialysate
Author
Holmar, Jana ; Uhlin, Fredrik ; Ferenets, Rain ; Lauri, Kai ; Tanner, Risto ; Arund, Jurgen ; Luman, Merike ; Fridolin, Ivo
Author_Institution
Dept. of Biomed. Eng., Tallinn Univ. of Technol., Tallinn, Estonia
fYear
2013
fDate
3-7 July 2013
Firstpage
6707
Lastpage
6710
Abstract
The aim of this study was to explore the possibility to determine the amount of total removed Indoxyl Sulphate (TR_IS) during dialysis session, an optical method utilizing absorbance and fluorescence spectral data of the spent dialysate was used. Eight uremic patients from Linköping, Sweden and 10 from Tallinn, Estonia, were studied during dialysis treatments. Dialysate samples were taken during each treatment and analyzed at a laboratory. Fluorescence and absorbance spectra of the spent dialysate were measured with spectrofluorophotometer and spectrophotometer. The spectral values were transformed into IS concentration using multiple linear regression model from the total material noted as optical method (Opt). IS concentration was estimated using high-performance liquid chromatography (HPLC) method as a reference. TR_IS values were calculated. Achieved results were compared regarding mean values and SD and collated with the amount of total removed urea value (TR_Urea) for the same dialysis procedures. Mean TR value±SD (mg) for urea was 28 947±9 241; TR for IS was 151.4±87.3 estimated by HPLC and 149.4±84.9 estimated by Opt. The TR_IS values were not significantly different (p≤0.05). This study indicates, that it is possible to estimate TR_IS using only spectral values of the spent dialysate and the parameter can be used for quantifying the elimination of protein bound uremic toxins during the dialysis procedure.
Keywords
biochemistry; chromatography; diseases; fluorescence; molecular biophysics; patient treatment; proteins; regression analysis; spectrochemical analysis; spectrophotometers; toxicology; absorbance spectral data; dialysis treatment; fluorescence spectral data; hemodialysis; high-performance liquid chromatography method; multiple linear regression model; optical method; protein bound uremic toxin; spectrofluorophotometer; spectrophotometer; spent dialysate; total removed indoxyl sulphate determination; total removed urea value; uremic patient; uremic toxin indoxyl sulphate estimation; Biomedical optical imaging; Estimation; Fluorescence; Kidney; Optimized production technology; Protein engineering; Proteins; Aged; Aged, 80 and over; Dialysis Solutions; Female; Humans; Indican; Male; Middle Aged; Renal Dialysis; Spectrometry, Fluorescence;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location
Osaka
ISSN
1557-170X
Type
conf
DOI
10.1109/EMBC.2013.6611095
Filename
6611095
Link To Document