• DocumentCode
    638767
  • Title

    A Digital Goniometer based on encoders for measuring knee-joint position in an orthosis

  • Author

    Dominguez, G. ; Cardiel, Eladio ; Arias, Sandra ; Rogeli, Pablo

  • Author_Institution
    Electr. Eng. Dept., Center for Res. & Adv. Studies (Cinvestav), Mexico City, Mexico
  • fYear
    2013
  • fDate
    12-14 Aug. 2013
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Angular measurements of knee joint are a key factor in orthoses design, actually is very important for human gait analysis in order to obtain a deep knowledge of the musculoskeletal system performance. Video-based motion analysis systems have been used as measurement tools to quantify the angle and movement of knee joint. Though this technique is good, it requires special equipment and high computational cost. This work introduces a novel method of knee joint measurement. The design is mainly based on the contactless magnetic absolute encoder AS5040 (Austria Microsystems®, USA), and the microprocessor type PIC16F877A. The developed device has a resolution of 0.35 degrees, quite enough for an orthosis that requires knee position measurements. The reliability of the system was evaluated by making: 1) Static measurements by using a mechanical goniometer as reference, in which a correlation up to 0.999 was obtained. 2) Dynamical measurements by performing flexion-extension movements by a healthy subject and comparing the records with a commercial motion analysis system (APAS®, USA). A correlation of 0.9943 was obtained. Besides, trials were performed by three subjects under natural gait.
  • Keywords
    angular measurement; biomedical equipment; biomedical measurement; gait analysis; goniometers; magnetic sensors; microcomputers; orthotics; position measurement; reliability; APAS; AS5040; PIC16F877A; angular measurements; digital goniometer; flexion-extension movements; human gait analysis; knee-joint position measurement; magnetic absolute encoder; motion analysis system; musculoskeletal system; orthosis; video-based motion analysis; Bars; Correlation; absolute encoder; angles measurement; gait analysis; goniometry; knee joint; orthosis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nature and Biologically Inspired Computing (NaBIC), 2013 World Congress on
  • Conference_Location
    Fargo, ND
  • Print_ISBN
    978-1-4799-1414-2
  • Type

    conf

  • DOI
    10.1109/NaBIC.2013.6617835
  • Filename
    6617835