DocumentCode :
64040
Title :
Mechanism of impulse voltage breakdown in high voltage vacuum interrupters with long contact gap
Author :
Yingyao Zhang ; Zhiyuan Liu ; Yingsan Geng ; He Yang
Author_Institution :
Dept. of Electr. Eng., Tongji Univ., Shanghai, China
Volume :
21
Issue :
2
fYear :
2014
fDate :
Apr-14
Firstpage :
906
Lastpage :
912
Abstract :
The objective of this paper is to propose a breakdown mechanism of lightning impulse voltage in high voltage vacuum interrupters (VIs) with long contact gap by complementing the Cranberg "clump" hypothesis with an impulse voltage and a non-uniform field. The Cranberg "clump" hypothesis assumed that the vacuum breakdown was due to the loosely adhering microscopic particles under a DC voltage and a uniform field. The microscopic particles might be torn from an electrode surface at a critical voltage. We considered the microscopic particles located at the area with the maximum electric field had the highest possibility to be accelerated. Therefore, the transit process of the micro-particles to the opposing electrodes was under a non-uniform field distribution driven by an impulse voltage. The rise rate of the impulse voltage applied was also considered. As a result, it was found that the breakdown voltage of a vacuum gap depends upon a 0.76 power of the gap length for the plate-to-plate contacts. The diameter of the contacts was 60 mm. The contact radius of curvature was 6 mm. In the same conditions, our previous experimental results showed that the impulse breakdown voltage was in a range of 0.70 to 0.79 power of the contact gap. So the experimental results supported the Cranberg hypothesis in its extension to the impulse breakdown under non-uniform field in high-voltage VIs. Thereafter, this proposed breakdown mechanism is a complement to the Cranberg "clump" hypothesis in terms of impulse voltage breakdown under a non-uniform field in high voltage VIs.
Keywords :
electric breakdown; electric fields; electrodes; vacuum interrupters; Cranberg clump hypothesis; DC voltage; breakdown voltage; electrodes; high voltage vacuum interrupters; impulse breakdown voltage; impulse voltage breakdown mechanism; lightning impulse voltage; long contact gap; maximum electric field; microparticles; microscopic particles; nonuniform field; nonuniform field distribution; plate-to-plate contacts; vacuum breakdown; Breakdown voltage; Electric fields; Electrodes; Rough surfaces; Surface roughness; Vacuum breakdown; Cranberg hypothesis; breakdown mechanism; impulse voltage; microscopic particles; non-uniform field; vacuum interrupters;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2013.003711
Filename :
6783086
Link To Document :
بازگشت