DocumentCode :
64485
Title :
Proposal for Measurement Method of Transfer Impedance of Current Probe
Author :
Sekiguchi, Hiroto ; Funaki, Tsuyoshi
Author_Institution :
Nat. Maritime Res. Inst., Tokyo, Japan
Volume :
56
Issue :
4
fYear :
2014
fDate :
Aug. 2014
Firstpage :
871
Lastpage :
877
Abstract :
This paper proposes a measurement method with a high reliability and reproducibility for the transfer impedance of current probe. The measurement method uses a vector network analyzer and a calibration fixture. The advantages of the proposed measurement method are the high reliability and reproducibility of measured results among different measurement systems, and the reduction of measurement error of the used measurement system. From the experimental measurements, it is shown that the proposed measurement method is more effective than the conventional methods.
Keywords :
calibration; electric current measurement; electric impedance measurement; measurement errors; network analysers; reliability; calibration fixture; current probe measurement method; measurement error; reliability; transfer impedance measurement method; vector network analyzer; Calibration; Current measurement; FCC; Frequency measurement; Impedance; Impedance measurement; Probes; Calibration fixture; current probe; measurement method; reliability; reproducibility; transfer impedance; vector network analyzer (VNA);
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/TEMC.2013.2295415