DocumentCode
646691
Title
Stirrer performance of reverberation chambers evaluated by time domain fidelity
Author
Esposito, G. ; Gradoni, Gabriele ; Moglie, Franco ; Mariani Primiani, V.
Author_Institution
Dept. of Inf. Eng., Univ. Politec. delle Marche, Ancona, Italy
fYear
2013
fDate
5-9 Aug. 2013
Firstpage
207
Lastpage
212
Abstract
The fidelity variation is considered inside a reverberation chamber. In particular, the scattering fidelity represents the decay law of the residual correlation between two cavity realizations. It is found that the fidelity is highly sensitive to stirrer geometry variations. Pertaining the chamber loading, the fidelity is also capable to reveal different location of absorbing materials. Results were also checked in terms of repeatability showing good reliability.
Keywords
electromagnetic wave scattering; reverberation chambers; absorbing materials; chamber loading; decay law; fidelity variation; repeatability; residual correlation; reverberation chambers; scattering fidelity; stirrer geometry variations; stirrer performance; time domain fidelity; Antenna measurements; Cavity resonators; Correlation; Frequency-domain analysis; Q-factor; Time measurement; Time-domain analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC), 2013 IEEE International Symposium on
Conference_Location
Denver, CO
ISSN
2158-110X
Print_ISBN
978-1-4799-0408-2
Type
conf
DOI
10.1109/ISEMC.2013.6670410
Filename
6670410
Link To Document