DocumentCode :
647997
Title :
Demand response potential of water heaters to mitigate minimum generation conditions
Author :
Wong, Simon ; Pelland, Sophie
Author_Institution :
CanmetENERGY, Natural Resources Canada, Varennes, QC, Canada
fYear :
2013
fDate :
21-25 July 2013
Firstpage :
1
Lastpage :
5
Abstract :
During periods of low electricity demand, particularly when demand drops below baseload supply levels, a system operator can encounter difficulties in efficiently dispatching its generating units. Referred to as `minimum generation conditions (MGC),´ these states are troublesome because they can lead to increased greenhouse gas emissions, depressed electricity prices, or additional barriers to renewables integration. This work explores the potential of using electric water heaters (EWHs), in a demand response (DR) role, to mitigate the number and severity of these MGCs. A detection method for finding MGCs is first applied to the system in Ontario, Canada. At 2018 renewables target levels, it was found that most MGCs would occur in the early morning of spring and fall. To significantly address this issue next generation EWHs employing DR would need a deadband of 10°C to enable the 800+MW required.
Keywords :
demand side management; electric heating; power generation dispatch; Canada; EWH; MGC; Ontario; demand response potential; depressed electricity prices; greenhouse gas emissions; minimum generation condition mitigation; water heaters; Electric potential; Electricity; Load management; Renewable energy sources; Resistance heating; Water heating; Water resources; load management; renewable energy; smart grids; surplus baseload; water heating;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Society General Meeting (PES), 2013 IEEE
Conference_Location :
Vancouver, BC
ISSN :
1944-9925
Type :
conf
DOI :
10.1109/PESMG.2013.6672552