This article presents the performance analysis of a conventional hybrid photovoltaic/thermal air heating collector. An excel spreadsheet is developed and various parameters are calculated for single-glass configuration. Results are presented to show the effect of various design and operational parameters on the performance of a system. These results are useful for designing such systems more scientifically.
Keywords
building integrated photovoltaics; cooling; solar absorber-convertors; solar cells; Polytechnic University of Bucharest; air cooling; conventional hybrid photovoltaic/thermal air heating collector; operational parameters; passive house; photovoltaic panels; single-glass configuration; Air cooling; photovoltaic panel; thermal efficiency;