DocumentCode :
65492
Title :
Iterative Reconstruction for X-Ray Computed Tomography Using Prior-Image Induced Nonlocal Regularization
Author :
Hua Zhang ; Jing Huang ; Jianhua Ma ; Zhaoying Bian ; Qianjin Feng ; Hongbing Lu ; Zhengrong Liang ; Wufan Chen
Author_Institution :
Sch. of Biomed. Eng., Southern Med. Univ., Guangzhou, China
Volume :
61
Issue :
9
fYear :
2014
fDate :
Sept. 2014
Firstpage :
2367
Lastpage :
2378
Abstract :
Repeated X-ray computed tomography (CT) scans are often required in several specific applications such as perfusion imaging, image-guided biopsy needle, image-guided intervention, and radiotherapy with noticeable benefits. However, the associated cumulative radiation dose significantly increases as comparison with that used in the conventional CT scan, which has raised major concerns in patients. In this study, to realize radiation dose reduction by reducing the X-ray tube current and exposure time (mAs) in repeated CT scans, we propose a prior-image induced nonlocal (PINL) regularization for statistical iterative reconstruction via the penalized weighted least-squares (PWLS) criteria, which we refer to as “PWLS-PINL”. Specifically, the PINL regularization utilizes the redundant information in the prior image and the weighted least-squares term considers a data-dependent variance estimation, aiming to improve current low-dose image quality. Subsequently, a modified iterative successive overrelaxation algorithm is adopted to optimize the associative objective function. Experimental results on both phantom and patient data show that the present PWLS-PINL method can achieve promising gains over the other existing methods in terms of the noise reduction, low-contrast object detection, and edge detail preservation.
Keywords :
computerised tomography; dosimetry; image denoising; image reconstruction; iterative methods; least squares approximations; medical image processing; object detection; phantoms; statistical analysis; CT scans; X-ray computed tomography; X-ray tube current; current low-dose image quality; data-dependent variance estimation; edge detail preservation; exposure time; iterative reconstruction; low-contrast object detection; modified iterative successive overrelaxation algorithm; noise reduction; penalized weighted least-squares criteria; phantom; prior-image induced nonlocal regularization; radiation dose reduction; statistical iterative reconstruction; Computed tomography; Educational institutions; Image edge detection; Image reconstruction; Noise; Phantoms; X-ray imaging; Penalized weighted least-squares; X-ray computed tomography; X-ray computed tomography (CT); penalized weighted least-squares; prior image; regularization; statistical iterative reconstruction; statistical iterative reconstruction (SIR);
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2013.2287244
Filename :
6646222
Link To Document :
بازگشت