Title :
Verification of bio-radiolocation method with respiratory plethysmography for non-contact remote breathing monitoring
Author :
Alekhin, M.D. ; Anishchenko, L.N. ; Zhuravlev, A.V. ; Tataraidze, A.B. ; Razevig, V.V. ; Vasilyev, I.A. ; Parashin, V.B. ; Ivashov, S.I. ; Bugaev, A.S.
Author_Institution :
Bauman Moscow State Tech. Univ., Moscow, Russia
Abstract :
Verification of bio-radiolocation with standard respiratory plethysmography during parallel registration of different types of breathing movements of subjects is performed. For all couples of synchronized signals corresponding to the both methods cross correlation and spectral functions are calculated and estimates of their generalized characteristics are defined. The obtained results revealed bio-radiolocation to be a reliable remote method for non-contact respiratory monitoring.
Keywords :
correlation methods; medical signal processing; patient monitoring; plethysmography; pneumodynamics; spectral analysis; bio-radiolocation method verification; breathing movements; cross correlation; noncontact remote breathing monitoring; noncontact respiratory monitoring; parallel registration; remote method; spectral functions; standard respiratory plethysmography; synchronized signals; Belts; Biomedical monitoring; Correlation; Monitoring; Plethysmography; Standards; Time series analysis; bio-radiolocation; correlation analysis; respiratory plethysmography; spectral analysis;
Conference_Titel :
Microwave Conference (EuMC), 2013 European
Conference_Location :
Nuremberg