Abstract :
Verification of bio-radiolocation with standard respiratory plethysmography during parallel registration of different types of breathing movements of subjects is performed. For all couples of synchronized signals corresponding to the both methods cross correlation and spectral functions are calculated and estimates of their generalized characteristics are defined. The obtained results revealed bio-radiolocation to be a reliable remote method for non-contact respiratory monitoring.
Keywords :
correlation methods; medical signal processing; patient monitoring; plethysmography; pneumodynamics; spectral analysis; bio-radiolocation method verification; breathing movements; cross correlation; noncontact remote breathing monitoring; noncontact respiratory monitoring; parallel registration; remote method; spectral functions; standard respiratory plethysmography; synchronized signals; Belts; Biomedical monitoring; Correlation; Monitoring; Plethysmography; Standards; Time series analysis; bio-radiolocation; correlation analysis; respiratory plethysmography; spectral analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference (EuMC), 2013 European
Conference_Location :
Nuremberg
Type :
conf
Filename :
6686753
Link To Document :
بازگشت