• DocumentCode
    656267
  • Title

    Closed-loop control modeling and dynamic performance analysis of 400Hz active filter

  • Author

    Zhong Chen ; Zhihui Wang ; Mengnan Li ; Miao Chen

  • Author_Institution
    Coll. of Autom. Eng., Nanjing Univ. of Aeronaut. & Astronaut., Nanjing, China
  • fYear
    2013
  • fDate
    3-6 Nov. 2013
  • Firstpage
    75
  • Lastpage
    80
  • Abstract
    The closed-loop control model of the active power filter (APF) is derived and analyzed in this paper. The analysis reveals the mechanism of the dynamic characteristics of this control method and indicates its poor performance in the 400Hz applications. Based on the classical control theory, the load active current feedforward compensation is introduced to solve the problem. The control principle and key parameters design are described. The simulation and experiment show that with feedforward compensation, the source current is responding well to the load change. The 400Hz aeronautical active power filter gets a good dynamic performance.
  • Keywords
    active filters; closed loop systems; compensation; feedforward; power filters; active current feedforward compensation; aeronautical active power filter; closed-loop control model; dynamic performance analysis; frequency 400 Hz; Active filters; Analytical models; Atmospheric modeling; Feedforward neural networks; Load modeling; Power filters; Time-frequency analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Future Energy Electronics Conference (IFEEC), 2013 1st International
  • Conference_Location
    Tainan
  • Print_ISBN
    978-1-4799-0071-8
  • Type

    conf

  • DOI
    10.1109/IFEEC.2013.6687482
  • Filename
    6687482