DocumentCode
656659
Title
Resonant substrate-integrated near-field sensors with improved sensitivity
Author
Haase, Nora ; Jacob, A.F.
Author_Institution
Inst. fur Hochfrequenztech., Tech. Univ. Hamburg-Harburg, Hamburg, Germany
fYear
2013
fDate
6-8 Oct. 2013
Firstpage
468
Lastpage
471
Abstract
The sensitivity of near-field sensors with substrate-integrated waveguide (SIW) resonator is studied. The structure of the sensors is based on a folded cylindrical cavity. Its shape and size are varied by exploiting the field symmetry of the excited mode. The resulting mode transformation is discussed. Several sensors of different geometries with resonant frequency close to 8 GHz are analyzed with respect to their sensitivity to ethanol and water. By adequately choosing the shape the sensitivity of the sensor, i.e., the shift of its resonant frequency caused by a dielectric sample, can be increased significantly.
Keywords
geometry; microwave resonators; sensors; substrate integrated waveguides; SIW resonator; ethanol; excited mode field symmetry; folded cylindrical cavity; geometries; mode transformation; resonant frequency; resonant substrate-integrated near-field sensors; sensitivity; sensors structure; substrate-integrated waveguide resonator; water; Microwave circuits; Q-factor; Resonant frequency; Sensitivity; Sensors; Substrates;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Integrated Circuits Conference (EuMIC), 2013 European
Conference_Location
Nuremberg
Type
conf
Filename
6687887
Link To Document