DocumentCode :
663107
Title :
Electrophysiological monitoring of cerebellar evoked potentials following fluid percussion injury
Author :
Ordek, Gokhan ; Groth, J.D. ; Pfister, Bryan J. ; Sahin, Mesut
fYear :
2013
fDate :
6-8 Nov. 2013
Firstpage :
973
Lastpage :
976
Abstract :
Cerebellum is highly susceptible to traumatic injuries, and yet it has rarely been studied in the context of traumatic brain injury (TBI). Much of the TBI research in the cerebellum has been conducted through histochemical techniques, particularly using selective protein staining. In this study, we investigated if fluid percussion injury (FPI) was detectable using electrophysiological recordings of the cerebellar activity with multi-contact array electrodes. Rats were chronically implanted with micro ECoG electrodes on the paramedian lobule (PML). The FPI was induced via a skull opening near the electrode implant on the cerebellum. Spontaneous and evoked potentials (EPs) featured almost immediate alterations in their waveform patterns after the delivery of pressure pulse. Recorded evoked potential amplitudes declined drastically by the next day. We also studied the linear correlation changes between all the electrode contact pairs and observed a significant decrease (R from > 0.7 to <; 0.4, p <;.001) as a result of injury. The results suggest that electrophysiological recording with chronic electrode implants can be used as a method of detection and longitudinal monitoring of subtle effects of TBI in the cerebellar circuits.
Keywords :
bioelectric potentials; biomedical electrodes; brain; injuries; microelectrodes; patient monitoring; TBI; cerebellar activity; cerebellar circuits; cerebellar evoked potentials; chronic electrode implants; electrocorticography; electrode contact pairs; electrophysiological monitoring; electrophysiological recordings; evoked potential amplitudes; fluid percussion injury; histochemical techniques; linear correlation changes; microECoG electrodes; multicontact array electrodes; paramedian lobule; pressure pulse delivery; selective protein staining; traumatic brain injury; waveform pattern; Animals; Arrays; Correlation; Electric potential; Electrodes; Fluids; Injuries; cerebellum; evoked potentials; micro ECoG; multi-electrode arrays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Neural Engineering (NER), 2013 6th International IEEE/EMBS Conference on
Conference_Location :
San Diego, CA
ISSN :
1948-3546
Type :
conf
DOI :
10.1109/NER.2013.6696098
Filename :
6696098
Link To Document :
بازگشت